Shanghai Xingshen Instrument Co., Ltd.
Products
Contact Us
  • Contact Person : Ms. Lu Linda
  • Company Name : Shanghai Xingshen Instrument Co., Ltd.
  • Tel : 86-21-58308800
  • Fax : 86-21-58309955
  • Address : Shanghai,Shanghai,20F Zhongxin Building, Lane 1862, South Pudong Road, Pudong New Area
  • Country/Region : China
  • Zip : 200122

LC3144LD Intelligent Displacer Level Transmitter

LC3144LD Intelligent Displacer Level Transmitter
Product Detailed
Related Categories:Level Measuring Instruments
LC3144LD Intelligent Displacer Level Transmitter 1.Suitable for Small Range, Low Density process conditions

Measure range:  liquid level: 0~5m   density: 0~0.3 to 0~2.0g/cm3                              Interface: density difference: 0~0.05 to 0~1.5g/ cm3Accuracy: A class: ±0.2%FS;  B Class: ±0.5%FS Output:  Analog--two wire 4~20mA DC;               Digital-- HART or FOXCOM Protocol;                FF Protocol.Process temp.: -196~420°C   Ambient temp.: -30~85°CSafety class: Intrinsically safe: ExiaIICT1-4; Explosion-proof:ExdIIT1-T5Enclosure: IP65 (NAME 4X)Connection flange: Material: carbon steel, 304SS, 316SS, 316L or on request

Model Table

LC3144LD

Intelligent Displacer Liquid Level (Interface )Transmitter   

Model Number

 

1  

HART

Communication

2

F. FIELDBUS

3

FOMCOM

 

Q235 steel

Body Material

2

321 SCS321 1Cr18Ni9Ti 1.4873

3

316Ti OCr18Ni12Mo2Ti 1.4571

4

316 SVS316 OOCr17Ni12Mo2 1.4401

5

316L SVS316L OOCr14Ni12Mo2 1.4435

6

other material to be specified.

 

External displacer side-side mounted

Mounting

C

External displacer side-bottom mounted

F

External displacer top-side mounted

G

External displacer top-bottom mounted

N

Internal displacer top mounted

 

For liquid level

Service

2

For interface

3

For density

 

4/4A

2.5MPa/Class 150LB ANSI

Pressure Rating

5/5A

4.0MPa/Class 300LB ANSI

6/6A

6.3MPa/Class 600LB ANSI

7/7A

16.0MPa/Class 900LB ANSI

8/8A

32.0MPa/Class 1500LB ANSI

9/9A

40.0MPa/Class 2500LB ANSI

 

T1

Normal temp.: -40°C~150°C

Process  Temperature

T2

High temp.: -150°C~420°C

T3

Low temp.: -196°C~40°C

 

O

no explosion-proof

Ex-proof Mark

D

explosion-proof :  ExdIICT1~T6

E

Intrinsically safe:  ExiaIICT1~T6

B

with safety barrier

 

0

without heating jacket

Optional Items

J1

heating jacket / process conn.

J2

heating jacket / process conn.JB/T82.1-94 DN15 PN1.0

 

 

 

Measure Range

 

 

Medium Density

( function(){ var aBigImageSrc = [ 'http://i01.i.aliimg.com/photo/v5/388076623_1/LC3144LD_Intelligent_Displacer_Level_Transmitter.jpg' , 'http://i01.i.aliimg.com/photo/v5/388076623_2/LC3144LD_Intelligent_Displacer_Level_Transmitter.jpg' , 'http://i01.i.aliimg.com/photo/v5/388076623_3/LC3144LD_Intelligent_Displacer_Level_Transmitter.jpg' , 'http://i01.i.aliimg.com/photo/v5/388076623_4/LC3144LD_Intelligent_Displacer_Level_Transmitter.jpg' , 'http://i01.i.aliimg.com/photo/v5/388076623_5/LC3144LD_Intelligent_Displacer_Level_Transmitter.jpg' , 'http://i01.i.aliimg.com/photo/v5/388076623_6/LC3144LD_Intelligent_Displacer_Level_Transmitter.jpg' ]; var oProductShow = new AE.run.minisite.productShow(); oProductShow.init( { 'aImgSrc': aBigImageSrc } ); } )(); LC3144LD Intelligent Displacer Level Transmitter



Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.